Autodesk Inventor Translation Report
|
|
Workflow Type: |
BIM building components |
Number Of Connections: |
17 succeed, 0 fail |
Translation Time: |
0:00:13.797 |
Number Of Faces: |
393 |
Sending System: |
Autodesk Inventor Professional 2016 |
Complexity Rating: |
Low |
Units: |
millimeter |
Bounding Box Size: |
695.624 mm x 1617.086 mm x 1988.314 mm |
|
Contents
|
The following table lists the file contents |
|
Generated Contents |
Status |
|
3D model |
Successful |
 |
2D front view |
Successful |
|
2D back view |
Successful |
|
2D left view |
Successful |
|
2D right view |
Successful |
|
2D top view |
Successful |
|
2D bottom view |
Successful |
|
|
Properties
|
Properties included on publish |
|
Identity Data |
|
Description |
BIM COMBIflo 150/300 |
Manufacturer |
Andrews Water Heaters |
Model |
COMBIflo 150/300 |
URL |
|
|
|
Connectors
|
Connector properties included on publish |
|
Duct Connector |
Connector:1 |
System Type |
Exhaust |
Loss Method |
None |
Loss Coefficient |
|
Pressure Drop |
|
Connection Type |
Undefined |
Flow Configuration |
Preset |
Flow |
|
Flow Factor |
|
Flow Direction |
Bidirectional |
Shape |
Round |
Height |
0.000 mm |
Width |
0.000 mm |
Radius |
100.000 mm |
Description |
Air Duct |
|
Pipe Connector |
Connector:2 |
System Type |
Hydronic Supply |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
28.500 mm |
Description |
Flow DN50 |
|
Pipe Connector |
Connector:3 |
System Type |
Hydronic Supply |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
29.500 mm |
Description |
Return DN50 |
|
Pipe Connector |
Connector:4 |
System Type |
Domestic Cold Water |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Fixture Units |
|
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
17.000 mm |
Description |
MCWS DN40 |
|
Pipe Connector |
Connector:5 |
System Type |
Domestic Hot Water |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Fixture Units |
|
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
17.000 mm |
Description |
DHW FLOW DN40 |
|
Pipe Connector |
Connector:6 |
System Type |
Domestic Hot Water |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Fixture Units |
|
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
10.500 mm |
Description |
DHW RETURN DN25 |
|
Pipe Connector |
Connector:7 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Undefined |
Shape |
Round |
Radius |
13.000 mm |
Description |
PT VALVE EXIT 28mm COPPER |
|
Pipe Connector |
Connector:8 |
System Type |
Undefined |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Undefined |
Shape |
Round |
Radius |
11.000 mm |
Description |
PT VALVE EXIT 22mm COPPER |
|
Pipe Connector |
Connector:9 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Threaded |
Shape |
Round |
Radius |
12.250 mm |
Description |
SAFETY VALVE TUNDISH DN20 |
|
Pipe Connector |
Connector:10 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Undefined |
Shape |
Round |
Radius |
14.000 mm |
Description |
DRAIN 28mm COPPER |
|
Pipe Connector |
Connector:11 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
Out |
Connection Type |
Coupling |
Shape |
Round |
Radius |
18.650 mm |
Description |
CONDENSATE OUTLET 41mm |
|
Pipe Connector |
Connector:12 |
System Type |
Other |
Allow Slope Adjustment |
True |
Loss Method |
None |
K Coefficient |
|
Pressure Drop |
|
Flow Configuration |
Preset |
Flow Factor |
|
Flow |
|
Flow Direction |
In |
Connection Type |
Threaded |
Shape |
Round |
Radius |
15.250 mm |
Description |
GAS INLET DN25 |
|
Electrical Connector |
Connector:13 |
System Type |
Power - Balanced |
Description |
MAINS POWER |
Voltage |
230.000 V |
Number of Poles |
3 |
Apparent Load |
|
Load Classification |
|
Motor |
True |
Power Factor |
|
Power Factor State |
Lagging |
|
Electrical Connector |
Connector:14 |
System Type |
Controls |
Description |
Local Process Bus (LPB) |
|
Electrical Connector |
Connector:15 |
System Type |
Communication |
Description |
VOLT FREE FAULT |
|
Electrical Connector |
Connector:16 |
System Type |
Communication |
Description |
VOLT FREE RUN |
|
Electrical Connector |
Connector:17 |
System Type |
Controls |
Description |
HEATING CIRCUITS 230V |
|