  • Up to 98% gross efficiency
  • Recovery rates of up to 1900 litres per hour
  • Vitraglas® lined storage tank and maintenance free, factory fitted Correx® anodes
  • Natural gas and LPG models available
  • Factory installed Hydrojet® sediment reduction system
  • Supported by a 3 year vessel warranty
  • WRAS approved and Energy Technology Listed*
  • For energy efficient, cost effective operation
  • Can satisfy the most demanding applications
  • Thermally efficient water storage. Protects glass lining and reduces service and maintenance time and costs
  • Also suitable for off mains gas areas
  • Gives a longer and more efficient working life
  • Peace of mind for the customer
  • Complies with the Water Supply (Water Fittings) Regulations and Scottish Byelaws and qualifies for the Government Enhanced Capital Allowance Scheme*

View product specification

When clicked this will open the product specification in PDF format.

 

 

Model

  Natural Gas: EC230/600 EC230/700 EC230/960 EC380/740 EC380/980 EC380/1220 EC380/1400 EC380/1900
  Propane: LEC230/600 LEC230/700 LEC230/960 LEC380/740 LEC380/980 LEC380/1220 LEC380/1400 LEC380/1900
Energy
Heat input (gross) natural/propane kW 36.6 43.9 58.3 43.9 58.3 73.2 85 118.7/117.2
Heat output natural/propane kW  35.1 41.3 54.2 43 57.1 71 79.1 117.2/111.2
Gross thermal efficiency natural/propane % 96 94 93 98 98 97 93/96 94
Standby heat loss Mj/month 626 626 626 626 793 793 793 817
NOx emissions (0% 02)  mg/kWh  44 44  44  44  44  44  44  44 
NOx emissions (0% 02) ppm 25 25 25 25 25 25 25 25
ErP
ErP efficiency rating    A  A  A  A  A  A  A  A
Gas data
Gas flow rate (natural gas) m3/h 3.41 4.09 5.43 4.09 5.43 6.82 7.92 11.33
Gas flow rate (propane) m3/h 1.39 1.67 2.22 1.67 2.22 2.78 3.12 4.46
Water
Storage capacity Litre 230 230 230 380 380 380 380 380
Recovery rate at 50ºC rise Litre/hr 600 700 960 740 980 1220 1400 1900
Recovery rate at 56ºC rise Litre/hr 537 632 830 658 874 1087 1211 1702
Operating pressure (unvented) bar 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
Minimum working pressure bar 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2
Maximum pressure bar 10 10 10 10 10 10 10 10
Dimensions 
Height mm 1448 1448 1448 1972 1972 1972 1972 1972
Diameter mm 718 718 718 718 718 718 718 718
Flue diameter mm 100/150 100/150 100/150 100/150 100/150 100/150 100/150 100/150
Side & rear service clearance mm 100 100 100 100 100 100 100 100
Top service clearance mm 450 450 450 450 450 450 450 450
Electrical
Fuse rating amp 5 5 5 5 5 5 5 5
Electrical power consumption W 120 120 120 120 120 120 120 120
Misc.
Noise level dBa 51 51 51 51 51 51 51 51
Weight full kg 450 450 450 760 760 760 760 760
Weight empty kg 259 259 259 408 408 408 408 408
Max. flue runs (Concentric)  16  16 16  16  16  16  16  16 
Max. flue runs (Conventional)  m 32   32   32   32    32    32    32    32   

 

Learn more about the ECOflo by downloading product literature. If you can’t find the literature you are looking for, or you have any questions, please contact your Area Sales Manager who will be able to help.

New multi level BIM files now available for this product

Download your Building Information Modeling (BIM) object(s) for this product. If you can’t find the BIM file you require, or you have any questions, please contact your Area Sales Manager who will be able to help.

01 - Text content 26773

LOD300 BIM files

Download CAD files for this product using the links below. To access CAD files you will need the correct software installed to allow you to open .dwg files such as AutoCAD. If you can’t find the CAD file you require, or you have any questions, please contact your Area Sales Manager who will be able to help

Interested in this product for your premises? Complete the form below and someone from the team will contact you shortly.

Alternatively, contact your Area Sales Manager about this or any of our products.

Can't find the product label or fiche you require below? Try our online calculation tool which allows you to create and download one for a completed system or package installation.

ECOflo energy labels

ECOflo 380-980 energy label updated 10/08/2015 (0.09MB) ECOflo 230-960 energy label updated 10/08/2015 (0.09MB) ECOflo 230-700 energy label LPG updated 10/08/2015 (0.09MB) ECOflo 230-700 energy label updated 10/08/2015 (0.09MB) ECOflo 380-980 energy label LPG updated 10/08/2015 (0.09MB) ECOflo 380-740 energy label LPG updated 10/08/2015 (0.09MB) ECOflo 230-600 energy label LPG updated 10/08/2015 (0.09MB) ECOflo 230-960 energy label LPG updated 10/08/2015 (0.09MB) ECOflo NG technical parameter sheet updated 10/08/2015 (0.03MB) ECOflo product range fiche updated 10/08/2015 (0.07MB) ECOflo 230-600 energy label updated 10/08/2015 (0.09MB) ECOflo 380-740 energy label updated 10/08/2015 (0.09MB) ECOflo LPG technical parameter sheet updated 10/08/2015 (0.03MB)

Andrews Water Heaters

Connect with us on LinkedinFollow us on TwitterWatch our videos on YouTube